Search results for "Reactive element"
showing 6 items of 6 documents
Metallic interconnects for solid oxide fuel cell: Effect of water vapour on oxidation resistance of differently coated alloys
2009
International audience; The need of interconnect to separate fuel and oxidant gasses and connect individual cells into electrical series in a SOFC stack appears as one of the most important point in fuel cell technology. Due to their high electrical and thermal conductivities, thermal expansion compatibility with the other cell components and lowcost, ferritic stainless steels (FSS) are nowconsidered to be among the most promising candidate materials as interconnects in SOFC stacks. Despite the formation at 800 ◦C of a protective chromia Cr2O3 scale, it can transform in volatile chromium species, leading to the lost of its protectiveness and then the degradation of the fuel cell. A previous…
Interconnecteurs métalliques de piles à combustible de type SOFC - Résistance à la corrosion et conductivité électrique à haute température
2009
The need of interconnect to connect individual cells into electrical series in a SOFC stack appears as one of the most important point in fuel cell technology. The main important criteria requires for interconnect is an excellent oxidation resistance in air and in H2/H2O. The goal of this study is to determine the influence on corrosion behaviour of a reactive element oxide coating (La2O3, Y2O3) realized by MOCVD on different metallic alloys like Crofer22APU, Haynes230 and Fe30Cr. The realisation of long ageing (7 700 and 15 400 hours) proved to be insightful. The corrosion kinetic experiments, the oxide scale characterisation and ASR measurements established that the presence of perovskite…
On the Effect of Surface Treatment to Improve Oxidation Resistance and Conductivity of Metallic Interconnects for SOFC in Operating Conditions
2008
International audience; Due to the reduction of operating temperature from 1000°C to 800°C, chromia forming alloys are the best candidates for interconnects in Solid Oxide Fuel Cells (SOFCs). These interconnects have to be operational in service conditions, at 800°C in air (cathode side) and in humidified hydrogen (anode side). The performance of the interconnect stainless steels is limited by the oxide scale formation (chromia), the low electronic conductivity of this scale and the possible volatility of chromium oxides. In the field of high temperature oxidation of metals, it is well known that the addition of a nanometric layer made of reactive element oxide such as, La2O3, Nd2O3 and Y2O…
Metallic interconnects for SOFC: Characterisation of corrosion resistance and conductivity evaluation at operating temperature of differently coated …
2007
Abstract One of challenges in improving the performance and cost-effectiveness of solid oxide fuel cells (SOFCs) is the development of suitable interconnect materials. Recent researches have enabled to decrease the operating temperature of the SOFC from 1000 to 800 °C. Chromia forming alloys are then among the best candidates for interconnects. However, low electronic conductivity and volatility of chromium oxide scale need to be solved to improve interconnect performances. In the field of high temperature oxidation of metals, it is well known that the addition of reactive element into alloys or as thin film coatings, improves their oxidation resistance at high temperature. The elements of …
Metallic interconnects for SOFC: competitive effect of water vapour and oxygen on the oxidation behaviour of ferritic stainless steel.
2009
Due to their low environmental impact, their high efficiency and their fuel flexibility, Solid Oxide Fuel Cells are studied for many years in order to supply electricity without fossil sources. The need of interconnect to create a stack (providing electrical connection between anode and cathode) and seal every single cell (having to avoid any contact between air and fuel) appears as a crucial point. Ferritic Stainless Steel (FSS) like Crofer22APU are considered as good candidates for interconnects. These chromia forming alloys have to be operational in the service conditions: 800°C in air (cathode side) and in humidified hydrogen (anode side). The performance of the interconnect stainless s…
Acoustic properties of plates with unevenly distributed macro perforations backed by woven meshes
2012
A hybrid model describing the acoustic properties of plates with macro-perforations that can be unevenly distributed on the plate surface and backed by woven or precision woven meshes with microscopic perforations is proposed. The plate perforations may be of circular or rectangular shapes. Since the perforated plate may not necessarily be considered as an equivalent fluid, its surface impedance is calculated by the Maa model [Noise Control Eng. J. 29, 77-84 (1987)], whereas the Johnson-Champoux-Allard model [J. Appl. Phys. 70, 1975-1979 (1991)] is used for the mesh. It is observed that the absorption of the carrying plate seems to depend on the hydraulic diameter of the perforations and no…